Tesla List wrote:
> 
> Subject:  Re: Secondary Specs
>   Date:   Wed, 16 Apr 1997 20:27:57 -0700
>   From:   "DR.RESONANCE" <DR.RESONANCE-at-next-wave-dot-net>
>     To:   "Tesla List" <tesla-at-pupman-dot-com>
> 
> to: Phil
> 
> Suggest 4 inch dia. SDR (sewer & drain) from plumbing supply store with
> a
> length of 32 inches.  Wind with #28 AWG polythermalize (200 degree C.).
> Start winding 3 inches from bottom and terminate 1 inch from top.  Total
> winding length is 28 inches.  Use .005 MFD cap with 30 ma xmfr and fixed
> sparkgap with 4-5 gaps.  Use muffin fan to blow 150 - 200 CFM air
> through
> sparkgap.  Terminate with 12 x 3 toroid.  Primary is 32 turns 1/2 copper
> strap (or 10 AWG house wiring).  Tap primary as necessary for best
> performance.
> 
> If available use 60 ma. xmfr with .01 MFD cap for best performance.  34
> inch spark with this xmfr and 22-24 inch spark with 30 ma xmfr.
> 
> Have fun.
> 
> DR.RESONANCE-at-next-wave-dot-net


Thank you, Doctor :-)  I feel better already!  As you might have seen,
my first effort now will be a baby 2.75".  Probably a 4" next.  Then a
6" etc etc

Yhanx for your recommendations.