[Prev][Next][Index][Thread]
Re: Cap Failure
You wrote:
> Probably not carbon tracking _thru_ the case in the latest failure,
> since the cap was resting on a thick HDPE sheet. In Richard Wall's
>case, thru-wall carbon tracking may have been a contributing factor.
>I've asked him if he had the cap resting on a conductive surface while
> operating the coil.
>
> In the latest failure, no obvious cause was apparent, but clearly
> something caused significant pressure rise in the cap. Closer
> examination will be done, and the capacitor will hopefully be
> salvageable.
>
> -- Bert --
The cap was flat on its side on 1/4" plywood which was on a concrete
floor. My cap was definitely salvagable and works quite well after the
casing rebuild. It's now in a wooden containment box.
RWW