[Prev][Next][Index][Thread]
Re: Filter Choke Design
-
To: tesla-at-grendel.objinc-dot-com
-
Subject: Re: Filter Choke Design
-
From: Bert Pool <nikki-at-fastlane-dot-net>
-
Date: Mon, 11 Mar 1996 21:43:04 -0500
-
>Received: from fastlane-dot-net (fastlane-dot-net [204.251.16.10]) by uucp-1.csn-dot-net (8.6.12/8.6.12) with ESMTP id UAA16057 for <tesla-at-grendel.objinc-dot-com>; Mon, 11 Mar 1996 20:40:56 -0700
At 10:02 AM 3/11/96 +0700, you wrote:
>>From ed-at-alumni.caltech.edu Sun Mar 10 11:13 MST 1996
>>Received: from alumnae.caltech.edu (alumnae.caltech.edu [131.215.50.235])
by uucp-1.csn-dot-net (8.6.12/8.6.12) with ESMTP id KAA02709 for
<tesla-at-grendel.objinc-dot-com>; Sun, 10 Mar 1996 10:28:37 -0700
>From: ed-at-alumni.caltech.edu (Edward V. Phillips)
>Date: Sun, 10 Mar 1996 09:27:21 -0800
>To: tesla-at-grendel.objinc-dot-com
>Subject: Re: Filter Choke Design
>
>Does anyone have any way of checking the effectiveness of
>magnetic core chokes working near saturation? I, too, suspect
>that the losses associated with saturation may help damp
>what could otherwise be some nasty transient effects. I
>wish I had a good high voltage divider for my scope.
>Ed Phillips
>
>
You might want to look at using a good commercial designed divider designed
for color television h.v. power supplies. You might start with the Phillips
Sylvania general replacement, Hi-Div-1, 240 megohms tapped at 40 megohms,
rated at 35 kv (you might want to use more than one). Last price I have is
about $11.00 USA.
They offer several different HV divider modules with varying values, the one
I show above is the most expensive.
They are readily available.
bert