To: tesla-at-grendel.objinc-dot-com, KLINEDA-at-univscvm.csd.scarolina.edu, QUANTUM-at-univscvm.csd.scarolina.edu, WMEYER-at-scientia.up.ac.za, bhaley-at-shore-dot-net, frerichs-at-zfe.siemens.de, froula-at-cig.mot-dot-com, haba-at-snakemail.hut.fi, jetter-at-ix-dot-netcom-dot-com, scott-at-csustan.csustan.edu
-
Subject: Re: Outside testing
-
From: Esondrmn-at-aol-dot-com
-
Date: Tue, 3 Oct 1995 16:59:36 -0400
-
>Received: from ns-1.csn-dot-net (root-at-ns-1.csn-dot-net [199.117.27.21]) by uucp-1.csn-dot-net (8.6.12/8.6.12) with SMTP id PAA21021 for <tesla-at-grendel.objinc-dot-com>; Tue, 3 Oct 1995 15:03:15 -0600
In a message dated 95-10-03 14:06:13 EDT, tesla-at-grendel.objinc-dot-com writes:
>Subject: Re: Outside testing
>
>> All of a sudden a massive bolt broke out from the
>> center of the secondary to the primary strike shield. I turned the
>> power off and refired it. It is difficult to get it to run without
>breakouts
>> happening from the coil itself. I even had the safety gap fire once.
>>
>> What is happening here? Too much power?
>
>I don't know if it's the same thing that I experienced at my much lower
>1kVA level, but I was having the same sort of problem (discharges from
>the middle of the secondary) until I raised my secondary up to loosen
>the coupling. When I did that, the spark-over stopped and I actually
>gained two inches or so of spark length.
>
>
>Steven Roys (sroys-at-radiology.ab.umd.edu)
>
>
Steven,
I originally experienced serious corona and breakdown problems between the
primary and the secondary until I raised the secondary up 3.0". This fixed
it. I don't know what's happening now.
Ed Sonderman