[Prev][Next][Index][Thread]
Wire Chart
-
To: tesla-at-grendel.objinc-dot-com
-
Subject: Wire Chart
-
From: richard.quick-at-slug-dot-org (Richard Quick)
-
Date: Thu, 26 Jan 1995 21:43:00 GMT
-
>Received: from uustar.starnet-dot-net by csn-dot-net with SMTP id AA16951 (5.65c/IDA-1.4.4 for <tesla-at-grendel.objinc-dot-com>); Thu, 26 Jan 1995 18:02:46 -0700
AWG D.C. OHMS WIRE DIAM
SIZE PER 1000 FT INCHES
1 .1264 .2893
2 .1593 .2576
3 .2009 .2294
4 .2533 .2043
5 .3195 .1819
6 .4028 .1620
7 .5080 .1443
8 .6405 .1286
9 .8077 .1144
10 1.018 .1019
11 1.284 .0907
12 1.619 .0808
13 2.042 .0720
14 2.524 .0641
15 3.181 .0571
16 4.018 .0508 Approx. Turns
17 5.054 .0453 Per Inch, Solid
18 6.386 .0403 Enamel covered
19 8.046 .0359 27
20 10.13 .0320 29
21 12.77 .0285 32
22 16.20 .0253 37
23 20.30 .0226 44
24 25.67 .0201 46
25 32.37 .0179 54
26 41.02 .0159 58
27 51.44 .0142
28 65.31 .0126 72
29 81.21 .0113
30 103.7 .0100 90
31 130.9 .0089
32 162.0 .0080
33 205.7 .0071
34 261.3 .0063
35 330.7 .0056
36 414.8 .0050
37 512.1 .0045
38 648.2 .0040
39 846.6 .0036
40 1079 .0031
41 1323 .0028
42 1659 .0025
43 2143 .0022
44 2593 .0020
45 3348 .00176
46 4207 .00157
47 5291 .00140
******************************************
For winding Tesla Secondary coils the general
consensus is to use number 22 AWG, or larger
diameter, double Formvar Magnet wire. Often
surplus partial spools of odd wire sizes are
found, so I took time to post a more complete
chart of AWG numbers and fractional diameters
than is usually available.
Richard Quick
... If all else fails... Throw another megavolt across it!