At 04:46 AM 11/8/2006, High Voltage list wrote:
>Original poster: Steven Roys <sroys@xxxxxxxxxx>
>
>
>
>---------- Forwarded message ----------
>Date: Wed, 8 Nov 2006 00:44:45 -0800
>From: Jim Mora <jmora@xxxxxxxxxxx>
>To: 'High Voltage list' <hvlist@xxxxxxxxxx>
>Subject: RE: The Geek Group High Voltage Capacitors, making a HV switch,
> (fwd)
>
>Hi Jim, Bert and et al,
>
>So what is a safe distance BTW components or more directly Buses with
>rounded edges or Hard copper pipe to go out and make a return path for a
>wire blow?. I seem to remember 40KV/in. I have the break down chart
>somewhere but that deals in needle points and spheres.
40 kV/inch is pretty bold. Breakdown in a uniform field is 70
kV/inch, and anything with curved components is hardly uniform. Your
40 kV/inch has a safety factor of less than 2.
One rule of thumb might be an inch per 10 kV. Watch the radius of
curvature for corona losses. At 20 kV, the *radius* needs to be on
the order of 1/4".. 1/2" diameter
Air insulated HV stuff tends to be quite bulky.