[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
Re: Cleansing Transformer Oil (fwd)
---------- Forwarded message ----------
Date: Thu, 18 Dec 2003 03:00:03 -0600
From: Dr. Resonance <resonance@xxxxxxxxxx>
To: High Voltage list <hvlist@xxxxxxxxxx>
Subject: Re: Cleansing Transformer Oil (fwd)
Take a sample to a local public utility company --- repair div. They can
do a standard 30 kV "cup" test to determine it's suitability. This a
standard of the industry test for xmfr oil.
Dr. Resonance
Resonance Research Corporation
E11870 Shadylane Rd.
Baraboo WI 53913
>
> I have some transformer oil that I'd like to put to use. The problem
> is that it has been stored outside in questinable containers. I am
> planning to heat the oil above 212 degrees Fahrenheit with some
> water-heater elements to drive off any absorbed moisture. How might I
> test the oil to see when it is finished drying? Thanks for the input.
> Oh- this is for a 75 kv project.
>
> Gregory