[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: Calculation of tank cap



Original poster: "Jim Lux by way of Terry Fritz <twftesla-at-qwest-dot-net>" <jimlux-at-earthlink-dot-net>

> >Original poster: "Jim Lux by way of Terry Fritz <twftesla-at-qwest-dot-net>"
> ><jimlux-at-earthlink-dot-net>
> 
> >You can run 4 in series by using the 600V winding to feed from one to
> >another.. The core will (potentially) run at high voltage, so the
> >outer transformers in this scheme need to be on suitable insulating
> >standoffs..
> 
> Hi Jim. I don't really understand what you're saying here. I had in
> mind to just wire the secondaries together and ground the midpoint of
> the two closest ones. This would put 10kv on the outer two? I don't
> see where the 600v winding fits in the scheme. Had in mind to just cut
> them out and do away with them.

See http://home.earthlink-dot-net/~jimlux/hv/xfrmr1.htm

>